A Systematic Sensitivity Analysis of the Performance of a Transcutaneous Energy Transmitter for Design Purposes

Daniela Wolter Ferreira, Luiz Lebensztajn

Abstract


This work studies a Transcutaneous Energy Transmitter (TET) which uses electromagnetic fields to transfer power from outside the body to an artificial organ in the body, working like a high frequency transformer with the skin being part of the magnetic coupling between the primary (external coil) and secondary (internal coil). For this reason, this project made two different kinds of analyses of the efficiency and the induced current density in a biologic tissue: first, simulations were performed using core types of distinct geometries, each with multiples sizes, ranking which type is more recommended; second, the sensitivity of the chosen core type to misalignments was evaluated for different dimensions. In addition, the sensitivity to the core permeability was also investigated for both analyses.

Full Text:

PDF

References


J. Ma, Q. Yang, and H. Chen, "Transcutaneous Energy and Information Transmission System with Optimized Transformer Parameters for the Artificial Heart``, IEEE Transactions On Applied Superconductivity, vol. 20, no. 3, pp. 798-801, 2010.

H. Miura, S. Arai, Y. Kakybari, F. Sato, H. Matsuki, and T. Sato, "Improvement of the transcutaneous energy transmission system utilizing ferrite cored coils for Artificial Hearts``, IEEE Transactions On Magnetics, v.42, no. 10, pp. 3578-3580, 2006.

H. Matsuki, M. Shiiki, K. Murakami, and T. Yamamoto, "Investigation of Coil Geometry for Transcutaneous Energy Transmission for Artificial Heart``, IEEE Transactions on Magnetics, vol. 28, no. 5, pp. 2406-2408, 1992.

G. E. Miller, "Artificial Organs`` (VA, USA. Morgan & Claypool publishers, 2006).

C. M. Zierhofer, and E. S. Hochmair, "Geometric approach for coupling enhancement of magnetically coupled coils``, IEEE Transactions on Biomedical Engineering, vol. 43, no. 7, 1996.

Institute for Applied Physics Nello Carrara. An Internet resource for the calculation of the dielectric properties of the body tissues in the frequency range 10 Hz–100 GHz. http://niremf.ifac.cnr.it/tissprop/.

K. Shiba, M. Nukaya, T. Tsuji and K. Koshiji, "Analysis of Current Density and Specific Absorption Rate in Biological Tissue Surrounding Transcutaneous Transformer for an Artificial Heart``, IEEE Transactions on Biomedical Engineering, 45(1), 2008, 205-213.

ICNIRP (International Commission on Non-Ionizing Radiation Protection), "Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz)``. Health Physics, 74(4), 1998, 494–522.

J. Jin, "The Finite Element Method in Electromagnetics``, John Wiley & Sons, Inc., 2nd edition, 2003.

T. M. Simon, F. Reitich, M. R. Jolly, K. Ito, H. T. Banks, "Estimation of the Effective Permeability in Magnetorheological Fluids``, Mathematical and Computer Modelling, 33 (1-3), pp. 273-284, 2001.




DOI: http://dx.doi.org/10.1590/S2179-10742013000200005

Refbacks

  • There are currently no refbacks.


© Copyright 2007-2016 JMOe Brazilian Microwave and Optoelectronics Society (SBMO) and Brazilian Society of Electromagnetism (SBMag)